4-Ch. Serial Server Card

4-Channel RS232/422/485 Serial Server (TC3847-1)

Compact and simple to configure, the TC3847-1 Serial Server transports four channels of RS-232 or RS-422/RS-485 data over existing Layer 2/Layer 3 networks. Each channel is independent, so it is possible to mix RS-232 and RS-422/RS-485. The TC3847-1 supports point-to-point serial tunneling and serial server configurations on a per port basis. For serial tunneling configurations, RS-232 or RS-422/RS-485 signals are transparently extended over IP networks. For serial server configurations, individual or multiple users can access their serial devices through the TC3847-1 over their network.

Features

  • Transports 4 Ch. RS-232 or RS-422/ RS-485 over Ethernet/IP
  • Supports RS-232 Handshaking (CTS/RTS)
  • 128 bit SSL Encryption for Management and Serial Data
  • Port Password Protection
  • Manage Via Web, SNMP or Telnet
  • Temperature and Power Consumption Monitoring
  • Extreme Temp (-40°C to +80°C) Optional
  • Meets or Exceeds IEC 61850-3, IEEE 1613 & NEMA TS-2 Standards
  • Member of the JumboSwitch® Product Family

Applications

Typical applications centered around transporting serial data over IP networks.

For example the TC3847-1 is often used in Utility, SCADA, Traffic Control and Process Control Networks to link RS-232 or RS-485 RTUs and PLCs to a Host CPU.

Specifications

Data Rates
  1. RS-232Up to 115Kbps
  2. RS-422/RS-485Up to 115Kbps
  3. Ethernet10/100Mbps, Full Duplex/Auto negotiation
Connection Capacity
  1. RS-232 or RS-422/RS-4854 Ports
Electrical
  1. RS-232 Interface
  2. ESD Protection+/-15KV HBM
  3. ConnectorRJ11F
  4. RS-422 Interface
  5. Termination (optional)100 Ohm
  6. ESD Protection+/-15KV HBM
  7. ConnectorRJ11F
  8. RS-485 Interface
  9. Termination (optional)100 Ohm
  10. ESD Protection+/-15KV HBM
  11. ConnectorRJ11F
  12. Ethernet Interface
  13. StandardsIEEE 802.3, 802.3u, 802.1p&Q
Regulatory Approval
  1. CE, FCC Part 15, CISPR, CLASS A, IEC 61850-3, IEEE 1613, NEMA TS-2
System
  1. Bit Error Rate1 in 1010 or Better
Diagnostic Functions
  1. Local and Remote Loopback for Serial Data
LEDs
  1. Unit StatusPWR (A, B), Alarm, Vcc, BP, MGM
  2. ChannelRx/Tx/Status
  3. EthernetLink/Act
Power
  1. Standard12VDC
  2. Optional24, -48 VDC, 90-260 VAC, 50/60Hz
  3. Power Consumption< 10W
Operating Temperature
  1. Hi-Temp-20°C to 70°C
  2. Extreme Temp-40°C to 80°C
Storage
  1. Temperature-40°C to 90°C
  2. Humidity95% non-condensing
Physical (4-Channel Standalone)
  1. Height(3.15 cm) 1.24"
  2. Width(17.78 cm) 7.0"
  3. Depth(22.86 cm) 9.0"